2-75
D3-D11 REG-HYB UK.INDD RH 06.09.2011
Regenerative and Hybrid Valves
Series D31NWR, D*1VWR, D*1VWZ
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Characteristics
The new series of regenerative and hybrid directional
control valves are available in four sizes:
D31NWR NG10 Hybrid function with
adaptor plate (see
chapter 12)
D41VWR, D41VWZ NG16
D91VWR, D91VWZ NG25
D111VWR, D111VWZ NG32
The innovative integrated regenerative function in the
A-line (optional) allows new energy saving circuits with
differential cylinders. The hybrid version can switch be-
tween regenerative mode and standard mode at any time.
Features
• Energy saving A-regeneration optionally integrated
• Switchable hybrid version
Further literature about the opportunities of energy
savings and more functional details of the integrated
regeneration is available on request.
D41VWR D41VWZ
Regenerative D*1VWR Hybrid D*1VWZ
T A P B
AB
T A P B
AB
Regenerative valve D*1VWR Hybrid valve D*1VWZ
Q
Q
Regeneration
Pump
A B
T P
D*1VWR (regenerative valve)
Cylinder extending
D*1VWZ (hybrid valve)
Cylinder extending Cylinder extending
regenerative mode standard mode
(high speed) (high force)
Q
Q
Regeneration
Pump
A B
T P
Q
Pump
A B
T P
Regenerative and Hybrid Valves
Series D31NWR, D*1VWR, D*1VWZ
2-76
D3-D11 REG-HYB UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Ordering Code
Spool
type
Series 3 spool
position
Spring offset in
position “0“.
Operated in position
“a“ or “b“.
Code Bore Size
D31NW Ø11mm NG10
D41VW Ø20mm NG16
D91VW Ø32mm NG25
D111VW Ø50mm NG32
Solenoid
options
Solenoid
voltage
24V =
Design
series
(not required
for ordering)
Pilot oil
supply and
drain options
Acces-
sories
Connector
as per
EN 175301-803,
without con-
nector
(Please order plug
separately)
Seals
Code Seals
N NBR
V FPM
Code Accessories
omit
Standard valve
w/o accessories
3A Pilot choke, meter-out
3B Pilot choke, meter-in
3C
Pilot with pressure
reducing valve
3D
3)
Stroke adjustment side B
3E
3)
Stroke adjustment side A
3F
3)
Stroke adjustment
side A and B
3R
meter-out + pressure
reducing valve
1T
meter-in + pressure
reducing valve
Code Solenoid option
omit Standard solenoid
T without manual override
Code Inlet Outlet
1 Internal External
2 External External
4 Internal Internal
5 External Internal
3)
not for D111VW
WJC
Regenerative function
Code Spool type
R01
a b 0
R04
R81
R82
Hybrid function
1) 2)
Code Spool type
Z01
a b 0
Z04
Z81
Z82
1)
not for D31NW
2)
For regenerative and hybrid function for D31NW (NG10) please
refer solutions with sandwich- and adaptor plates "H10-1666L /
H10-1662 / A10-1664 / A10-1665L" in chapter 12.
D31NW spool type: R01 , R04
R81 , R82
2-77
D3-D11 REG-HYB UK.INDD RH 06.09.2011
Regenerative and Hybrid Valves
Series D31NWR, D*1VWR, D*1VWZ
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Technical Data
General
Design Directional spool valve
Actuation Solenoid
Series
D31NW D41VW D81/91VW D111VW
NG10 NG16 NG25 NG32
8.1 10.3 18.6 68.0
DIN 24340 A10 DIN 24340 A16 DIN 24340 A25 DIN 24340 A32
ISO 4401 ISO 4401 ISO 4401 ISO 4401
NFPA D05 NFPA D07 NFPA D08 NFPA D10
Size
Weight [kg]
Mounting interface
CETOP RP 121-H
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+50
MTTF
D
value [years] 75
Hydraulic
Max. operating pressure
[bar]
[bar]
Pilot drain internal: P, A B, X: 350; T, Y: 105 (D31NW: P, A, B, X: 315; T, Y: 140)
Pilot drain external: P, A B, T, X: 350; Y: 105 (D31NW: P, A, B, T, X: 315; Y:140)
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid temperature [°C] -25 ... +70
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Flow max. [l/min]
170 300 700 2000
72...422* up to 200* up to 800* up to 5000*
7 5
Leakage at 350 bar (per flow path) [ml/min]
*depending on spool
Minimum pilot supply pressure
[bar]
Static / Dynamic
Step response at 95% [ms] Energized / De-energized
DC solenoids Pilot pressure 50 bar
50 / 60 95 / 65 150 / 170 470 / 390
50 / 60 75 / 65 110 / 170 320 / 390
50 / 50 60 / 65 90 / 170 210 / 390
50 / 50 60 / 65 85 / 170 200 / 390
30 / 50 75 / 55 130 / 155 450 / 375
30 / 50 65 / 55 90 / 155 300 / 375
30 / 50 40 / 55 70 / 155 190 / 375
30 / 50 40 / 55 65 / 155 180 / 375
100 bar
250 bar
350 bar
AC solenoids Pilot pressure 50 bar
100 bar
250 bar
350 bar
Electrical characteristics
Duty ratio 100% ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP 65 in accordance with EN 60529
(with correctly mounted plug-in connector)
Supply voltage / ripple [V] 24 V =
Tolerance supply voltage [%] ±10
Current consumption hold [A] 1.29
Current consumption in rush [A] 1.29
Power consumption hold [W] 31
Power consumption in rush [W] 31
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
Duty ratio 100%
Protection class IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
D41 D91 D111
Supply voltage [V] 24 24 24
Tolernace supply voltage [%] ±10 ±10 ±10
Current consumption [A] 1.21 0.96 1.29
Power consumption [W] 29 23 31
Solenoid connection Connector as per EN 175301-803
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Electrical characteristics hybrid option
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
Regenerative and Hybrid Valves
Series D31NWR, D*1VWR, D*1VWZ
2-78
D3-D11 REG-HYB UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Flow Curve Diagrams
Flow curves measured with spool R01, R04, Z01, Z04
D91VW
D41VW
D111VW
D31NW on request
2-79
D3-D11 REG-HYB UK.INDD RH 06.09.2011
Regenerative and Hybrid Valves
Series D31NWR, D*1VWR, D*1VWZ
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Pilot Flow
open, closed
Pilot oil
Inlet
Drain
B C
internal
external
internal
external
external
external
internal
internal
D31NWR
D41VWR D41VWZ
D91VWR D91VWZ
D111VWR D111VWZ
Pilot oil inlet (supply) and outlet (drain)
Regenerative and Hybrid Valves
Series D31NWR, D*1VWR, D*1VWZ
2-80
D3-D11 REG-HYB UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Surface finish
BK320
4x M10x60
2x M6x55
DIN 912 12.9
63 Nm ±15%
13.2 Nm ±15%
NBR: SK-D41VW-N-91
FPM: SK-D41VW-V-91
D41VWR/Z
* Please add for each sandwich plate +40mm (pressure reducing valve, choke valve meter-in/-out).
D31NWR
Regenerative and hybrid function with additional plate ”H10-1666L / H10-1662 / A10-1664 / A10-1665L“, see
chapter 12
Surface finish
BK385
4x M6x40
DIN 912 12.9
13.2 Nm
NBR: SK-D31NW-N-91
FPM: SK-D31NW-V-91
Dimensions
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
Ø10.5
94
188*
70
12
72
31
68
101
Ø6.6
122
155
Stroke
adjustment
AB
BA
* Please add for each sandwich plate +40mm (pressure reducing valve, choke valve meter-in/-out).
2-81
D3-D11 REG-HYB UK.INDD RH 06.09.2011
Regenerative and Hybrid Valves
Series D31NWR, D*1VWR, D*1VWZ
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Dimensions
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
D91VWR/Z
Surface finish
BK360
6x M12x75
DIN 912 12.9
108 Nm
±15%
NBR: SK-D81VW-N-91 / SK-D91VW-N-91
FPM: SK-D81VW-V-91 / SK-D91VW-V-91
* Please add for each sandwich plate +40mm (pressure reducing valve, choke valve meter-in/-out).
D111VW
The space necessary to remove the plug as per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
Surface finish
BK386
6x M20x90
DIN 912 12.9
517 Nm
±15%
NBR: SK-D111VW-N-91
FPM: SK-D111VW-V-91
* Please add for each sandwich plate +40mm (pressure reducing valve, choke valve meter-in/-out).
2-82
D3-D11 REG-HYB UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Notes