2-77
D3-D11 REG-HYB UK.INDD RH 06.09.2011
Regenerative and Hybrid Valves
Series D31NWR, D*1VWR, D*1VWZ
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Technical Data
General
Design Directional spool valve
Actuation Solenoid
Series
D31NW D41VW D81/91VW D111VW
NG10 NG16 NG25 NG32
8.1 10.3 18.6 68.0
DIN 24340 A10 DIN 24340 A16 DIN 24340 A25 DIN 24340 A32
ISO 4401 ISO 4401 ISO 4401 ISO 4401
NFPA D05 NFPA D07 NFPA D08 NFPA D10
Size
Weight [kg]
Mounting interface
CETOP RP 121-H
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+50
MTTF
D
value [years] 75
Hydraulic
Max. operating pressure
[bar]
[bar]
Pilot drain internal: P, A B, X: 350; T, Y: 105 (D31NW: P, A, B, X: 315; T, Y: 140)
Pilot drain external: P, A B, T, X: 350; Y: 105 (D31NW: P, A, B, T, X: 315; Y:140)
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid temperature [°C] -25 ... +70
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Flow max. [l/min]
170 300 700 2000
72...422* up to 200* up to 800* up to 5000*
7 5
Leakage at 350 bar (per flow path) [ml/min]
*depending on spool
Minimum pilot supply pressure
[bar]
Static / Dynamic
Step response at 95% [ms] Energized / De-energized
DC solenoids Pilot pressure 50 bar
50 / 60 95 / 65 150 / 170 470 / 390
50 / 60 75 / 65 110 / 170 320 / 390
50 / 50 60 / 65 90 / 170 210 / 390
50 / 50 60 / 65 85 / 170 200 / 390
30 / 50 75 / 55 130 / 155 450 / 375
30 / 50 65 / 55 90 / 155 300 / 375
30 / 50 40 / 55 70 / 155 190 / 375
30 / 50 40 / 55 65 / 155 180 / 375
100 bar
250 bar
350 bar
AC solenoids Pilot pressure 50 bar
100 bar
250 bar
350 bar
Electrical characteristics
Duty ratio 100% ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP 65 in accordance with EN 60529
(with correctly mounted plug-in connector)
Supply voltage / ripple [V] 24 V =
Tolerance supply voltage [%] ±10
Current consumption hold [A] 1.29
Current consumption in rush [A] 1.29
Power consumption hold [W] 31
Power consumption in rush [W] 31
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
Duty ratio 100%
Protection class IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
D41 D91 D111
Supply voltage [V] 24 24 24
Tolernace supply voltage [%] ±10 ±10 ±10
Current consumption [A] 1.21 0.96 1.29
Power consumption [W] 29 23 31
Solenoid connection Connector as per EN 175301-803
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Electrical characteristics hybrid option
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.